FIRE ALARM SYSTEM

notifier-1

 

Fire Alarm Control Panels


onxy-2

 

Intelligent fire alarm control panels, featuring industry-leading smoke sensing technology.

 

Intelligent Addressable FACP, 1 Loop
 
Intelligent Addressable FACP, 1-2 Loop
 
Intelligent Addressable FACP, 1-10 Loop
 


convent-3

 

Conventional fire alarm panels, fire alarm panel communicators, and releasing panels.

 

Agent Release Control Panel
 
2-Zone Fire Alarm Control Panel
 
4-Zone Fire Alarm Control Panel
 
5-Zone Fire Alarm Control Panel
 
10-Zone Fire Alarm Control Panel
 


 

 
Fire Alarm Peripheral Devices

int-4

Intelligent Devices

 

 
Control Module and Relay Module
 
Monitor Modules
 
Addressable Photoelectric Smoke Detector
 
Addressable Thermal Detectors
 
Fault Isolator Module
 

 

Conventional

 

Photoelectric Smoke Detectors
 
Rate-Anticipation Heat Detectors
 
Mechanical Heat Detectors
 
Beam Detector
 
Manual Fire Alarm Stations
 
Photoelectric Smoke Detectors
 
Manual Fire Alarm Pull Stations
 

 

Notification Appliances

 


 

 
Fire System Accessories

int-4

Remote Annunciators

 

 
80-Character LCD Fire Annunciator
 
Lamp Driver Modules
 
80-Character LCD Serial Annunciator
 

 

Power Supplies and Batteries

 

Auxiliary Power Supply
 
Power Supply
 
6-Amp and 8-Amp 24-Volt Remote Power Supplies
 


 

 

fire-lite-6

 

Addressable Fire Alarm Control Panels


ms-7

 

Intelligent Addressable FACP, 1 Loop
 
Intelligent Addressable FACP, 1-2 Loop
 


 

Conventional Fire Alarm Control Panel


ms-7

 

Fire Alarm Control Panel, 2-Zone
 
Fire Alarm Control Panel, 4-Zone
 
Fire Alarm Control Panel, 5-Zone
 
Fire Alarm Control Panel, 10-Zone
 


 

Releasing Control Panel


ms-7

 

Agent Release Control Panel
 


 

Pull Station


ms-7

 

Manual Fire Alarm Pull Stations
 


 

Addressable Modules


ms-7

 

Monitor Modules
 
Control Module
 
Relay Module
 
Fault Isolator Module
 


17-sys-sen

Conventional Detectors


18-detec

Photoelectronic Smoke Detector
 
Photoelectronic Smoke Detector, Low Profile
 
Fixed Temperature and ROR Heat Detector
 

 

2-wire Base Detector (For 882)
 
2-wire Base Detector (For 2151 and 5151)
 

 

135°C Fixed Temp. and ROR Heat Detector, Single
 
194°C Fixed Temp. and ROR Heat Detector, Single
 
135°C Fixed Temperature Heat Detector, Single
 
194°C Fixed Temperature Heat Detector, Single
 
135°C Fixed Temp. and ROR Heat Detector, Dual
 
194°C Fixed Temp. and ROR Heat Detector, Dual
 
135°C Fixed Temperature Heat Detector, Dual
 
194°C Fixed Temperature Heat Detector, Dual
 

 


convent-3

Intelligent Base Detector (For FSP-851, FST-851)
 


 
Beam

int-4

 

Beam Detector
 


 
AV (Notification Devices)

int-4

Horn, Red
 
Horn, Red, Outdoor
 
Horn Strobe, Red
 
Horn Strobe, Red, Outdoor
 
Horn Strobe, White
 
Speaker, Red only
 
Speaker, White only
 
Strobe, Ceiling, Red
 
Strobe, Ceiling, White
 
Strobe, Wall, Red
 
Strobe, Wall, White
 
Speaker w/ Strobe, Wall, Red
 
Speaker w/ Strobe, Ceiling, White
 
Speaker w/ Strobe, Ceiling, White, Plain
 


 

 

Duct Detector

int-4

 

2-wire Photoelectric Duct Detector
 


Alarm Bell

int-4

 

Alarm Bell
 
 


17-sys-sen

Conventional Fire Alarm Control Panels


18-detec

Fire Alarm Control Panel 10-30 Zones
 
10-Zones EXPANDER CARD
 
Remote Annunciator
 

 


 

OTHERS

save-8

Energy-saving project


 

Global warming that we are experiencing today was even more intensified by the human energy consumption and the significant change of the nature. Especially, the rapid increase of human power usage from the past is the main factor of the severity of the problem increase.

 

One of the outcomes from the electricity use is Harmonics. We could not prevent the harmonics because harmonics will be generated and accumulated in the electric systems every time the electronic devices are used. The effect of the harmonics will gradually impact the whole electric system and resulting in system malfunction in the long term.

 

From the research, it is shown that 3rd Harmonic is the series that accumulated mostly in the system. The example of the electric devices that create these harmonics are computers, light bulbs, air conditionings, machine and other motor devices, etc.

 

The impact of the harmonics on the operation of the electric power systems are shown as followings;

– The overheating of transformer
–The rise of the electric bill
– Reducing electronic devices and power system efficiency
– Decrease the consistency of electronic devices and electric system
– Shortening the lifetime of electric devices
– Decrease capacitor bank efficiency
– Lower motor performance

 

E-Saving is the harmonic blocking device which helps to decrease harmonic distortion as well as filter the harmonics to enter through the electric system. Therefore, the installation of E-Saving will reduce the electricity loss, decrease the electric bills and improve the stability and efficiency of electronic equipment and electrical systems in long-term.

 

Objective.
1.To reduce the electricity loss
2. To decrease the electric bill
3. To enhance the electrical system and electronic devices performance
4. To extend the lifetime of electrical equipments
5. To increase the stability of the power system

 

Quality.

1. To improve power quality
2. To reduce the overheat or the high-temperature in transformer
3. To improve the stability of power factor and capacitor bank
4. To increase the performance of circuit breaker in electric power system

DOWNLOAD

Download detail

 

 


Monitoring&Data logger


exit-12

FEATURE

• Automatic Monitoring and Control Output by Level of Temperature and Humidity Sensor.
• Automatic Monitoring and Control Output by Power Line Sensor.
• Automatic Monitoring and Control Output by Digital Input.
• Support Monitoring and Control System via Internet and Intranet Network.
• Support Monitoring and Control System via Web Application.
• Support Monitoring and Control System via Map System.
• Support Monitoring and Control System via Standalone.
• Support Monitoring and Control System via Client Direct.
• Support Monitoring and Control System via Mobile and Smartphone.
• Support Monitoring and Control System via SMS Alert and Email.
• Support Monitoring and Control System via Data Logger of Event or Real Time.
• Automatic Status Report on LCD.
• Status Report on Query via Web.
• Remote I/O.
• Remote Configurable.

More


 

Monitoring reference




 

 

 

 

Gaseous Fire Suppression System


 

Gaseous fire suppression bannerKidde_Logo

 

In Gaseous Fire Systems, we are trained to design, supply, installation, testing and commissioning of all Gaseous Suppression System. Gaseous Suppression System are classified into two groups namely Chemical gas and Inert gas.

 

FM-200 and Novec 1230 systems which are classified under the Chemical Gas efficiently between 5% to 10% Design Concentration. These two systems are super-pressurized to 25 bar with nitrogen at 21°C. While Argonite, Inergen, Nitrogen and High Pressure C02 systems are classified under the Inert Gas. These cylinders are pre-filled with 150bar, 200bar and 300bar. These gases are basically obtained naturally in the atmosphere.

 

Both FM-200 and Novec 1230 are Zero Ozone Depletion Potential (ODP) and having very Low Global Warming Potential (GWP). However, Inert Gases have both Zero Ozone Depletion Potential (ODP) and Zero Global Warming Potential (GWP).

 

Related Documents

 

KFP HPC02 Carbon Dioxide Fire Suppression Systems

KFP GX20 FM-200 Fire Suppression System for use with DuPont FM200

KFP ARGONITE-C60 Inert Gas Fire Suppression System with Controlled Flow Technology

NOVEC-Fire Suppression System Engineered for use with 3M Novec 1230 Fire Protection Fluid